For research use only. Not for human or animal consumption.
What it is
Retatrutide is a synthetic peptide supplied as a lyophilised powder. The block below is the identity a certificate of analysis has to agree with.
- Name: Retatrutide
- CAS number: 2381089-83-2
- Molecular formula: C221H342N46O68
- Average molecular mass: 4,731.33
- Form: lyophilised powder
- Appearance recorded on the current lot certificate: white lyophilized powder
- Storage: −20°C, desiccated, protected from light
Two of those entries do the work on a certificate. The formula fixes the atom count. The average molecular mass is what that atom count sums to — and it is the value every figure on an identity determination gets compared against. Knowing how that comparison is made is where the confusion this page exists to fix begins.
Why a big peptide looks small on a mass spectrum
The current lot certificate lists four mass-confirmation ions. Two of them are m/z 1183.500 and m/z 1577.800. A buyer expecting something near 4,731 reads 1183, arrives at roughly a quarter of the stated molecular mass, and concludes the vial holds a much smaller molecule than the label claims. That conclusion is wrong. The gap is a property of the instrument, not of the sample.
A mass spectrometer does not weigh molecules. It weighs ions, and it reports the ratio of an ion’s mass to its charge: m/z, not m. Electrospray ionisation puts the charge on by adding protons, and a peptide of this size leaves the source carrying several at once. Each proton adds about 1.008 daltons to the mass and one unit of charge to the divisor.
Three protons, the 3+ ion:
(4,731.33 + 3 × 1.008) ÷ 3 = 4,734.354 ÷ 3 = 1,578.12
Four protons, the 4+ ion:
(4,731.33 + 4 × 1.008) ÷ 4 = 4,735.362 ÷ 4 = 1,183.84
The certificate prints 1577.800 and 1183.500. Those are the same molecule read twice, at two charge states, by an instrument that divides before it prints.
Run the arithmetic backwards, which is the check worth learning, because it works on any certificate for any peptide:
1,577.800 × 3 − (3 × 1.008) = 4,730.38 1,183.500 × 4 − (4 × 1.008) = 4,729.97
Both land within about 1.4 daltons of 4,731.33 — under 0.03%. The 3+ ion recovers a mass 0.95 daltons low, the 4+ ion 1.36.
The two ions that do not reconstruct
The certificate prints four ions, not two. Beside 1183.500 sits 1193.000, and beside 1577.800 sits 1585.400. Neither of those recovers 4,731.33 as a plain protonated ion — run 1,585.400 × 3 − 3.024 and the answer is 4,753.18, nearly twenty-two daltons high.
That is what an alkali-metal adduct looks like. Electrospray will put a sodium or a potassium ion on a peptide in place of one of the protons, and the substitution adds the difference between the two masses to the neutral: 21.98 daltons for sodium, 38.09 for potassium. Calculate where those species land and both extra ions are accounted for:
[M+2H+Na]3+ (4,731.33 + 2 × 1.008 + 22.99) ÷ 3 = 1,585.45 [M+3H+K]4+ (4,731.33 + 3 × 1.008 + 39.10) ÷ 4 = 1,193.36
The certificate’s ion list includes a [M+3H+K]4+ species. The two assignments above are arithmetic performed on the printed numbers, not annotations read off the document — which is the reason for doing them rather than reading annotations on trust. Adducts are routine in electrospray, and an ion that does not reconstruct is more often an adduct than a discrepancy.
The leftover fraction
Four ions, four calculated values, and every printed figure sits at or just below the one it belongs to:
printed 1,183.500 calculated 1,183.84 −0.34 printed 1,193.000 calculated 1,193.36 −0.36 printed 1,577.800 calculated 1,578.12 −0.32 printed 1,585.400 calculated 1,585.45 −0.05
Three of the four are low by about a third of an m/z unit; the fourth by 0.05. An offset that is near-constant in m/z rather than in mass is the signature of instrument calibration, or of centroiding an isotope envelope the scan did not resolve. It is not the signature of a different molecule. Two contributors are routine at this size. A peptide of this formula carries an isotope envelope roughly three daltons wide — carbon-13 is about 1.07% of natural carbon, and across 221 carbon atoms the most abundant single ion carries two of them and sits about 0.85 daltons below the average mass, which is a mean across the whole envelope. Separately, a printed m/z carries the instrument’s own calibration error. Neither changes the assignment.
Four rules, and they generalise past this compound
- A printed m/z value means nothing without its charge state, and the charge state is not the whole annotation. The charge gives the divisor; the species — which protons, which adducts — is what the reconstruction depends on. 1183.500 is either a 1,183-dalton molecule or a 4,731-dalton one carrying four charges.
- An ion that does not reconstruct is not automatically a failure. Before you call it a discrepancy, calculate where the common adducts fall: sodium in place of a proton adds 21.98 daltons to the neutral mass, potassium 38.09.
- Two charge states reconstructing to the same neutral mass is a self-consistency check. It confirms the charge assignment, because a wrong z will not reconcile across two different charge states. It is not two independent measurements — both ions come from the same run and share its calibration.
- On a molecule of this size, a recovered mass inside a couple of daltons of the reference value is agreement. The isotope envelope alone is about three daltons wide, and whole-dalton thinking does not survive contact with it.
How to read this compound’s certificate
Identity and purity answer different questions. The current certificate reports 99.72% by HPLC with UV detection, and a separate identity determination by LC-MS. A purity figure is an area proportion: of everything the detector saw, this fraction eluted in the main peak. It does not say which molecule that peak is. Identity is the determination that tests whether the main peak carries the expected molecular mass, and it is the one the ion list above supports. A mass match is a strong constraint, not a proof of sequence — compounds of identical composition, sequence-permuted analogues among them, share the same mass. Sequence-level confirmation takes MS/MS fragmentation, or co-elution with an authentic reference standard, and a certificate reporting intact mass alone has not established that. A 99.72% figure attached to the wrong compound is 99.72% of the wrong compound. Both determinations belong on the page, each with its method printed beside it, and this certificate prints them: HPLC with UV detection for purity, LC-MS for identity.
Net content, purity and the label figure are three different quantities. The certificate reports net content of 13.09 mg; the vial label states 10 mg. Those two figures answer different questions and should not be expected to match. Net content is the weighed mass of the lyophilised solid, which also carries counter-ion and residual water. The label figure is a nominal peptide target. A purity percentage does not close the gap either: 99.72% is an area proportion among the species the UV detector saw, and it does not count counter-ion, residual water or residual solvent, all of which are on the balance when net content is weighed. So 13.09 mg of solid at 99.72% area purity is not 13.05 mg of peptide — the non-chromophoric fraction is simply not in that measurement. Net content says what is in the vial; purity says what proportion of the eluting material was the main peak. A certificate reporting one and not the other has answered half the question. And a net content figure identical to the nominal label to the digit, lot after lot, is worth a question — it may be rounding, or it may not be a measurement at all.
Identifiers on a listing are not the certificate. A certificate is the record of one submission. This lot’s certificate records material received 2026-07-24 and reported 2026-07-28, and it describes what the laboratory received on that date and nothing else. Product listings carry their own identifiers and their own dates, maintained separately from the laboratory’s record. Where a date or an identifier on a product listing does not line up with the certificate, that is a question to put to the seller rather than a difference to reconcile by guessing. The certificate is the document carrying a laboratory’s name and a chemist’s signature.
A name, a signature and a lookup code are three separate checks — on who is accountable, not on what is in the vial. The laboratory on this certificate is Freedom Diagnostics Testing, and naming it makes the report attributable to an organisation that can be contacted and asked. The signature — here a principal chemist’s — attaches a person to the finding. The accession number, 2607240053, retrieves the record from the laboratory’s own domain, which matters more than either: a PDF forwarded by a seller can be edited, while a record retrieved from the issuing laboratory’s own domain is not under the seller’s control. Confirm that the domain is the laboratory’s and not a lookalike before trusting what it returns, then read the document. None of these three settles what is in the vial. The ions do that.
Common questions
Why does a 4,731-dalton peptide appear at 1183? Because the instrument reports mass divided by charge. At four protons, (4,731.33 + 4.032) ÷ 4 = 1,183.84.
Does a purity percentage confirm identity? No. Purity is the proportion of detector area in the main peak. Identity is a separate determination — LC-MS on this certificate — which tests whether that peak carries the expected molecular mass. A mass match is consistent with the stated compound; sequence-level confirmation takes MS/MS or an authentic reference standard.
What if a printed ion does not reconstruct to the neutral mass? Check the alkali-metal adducts before calling it a discrepancy. Sodium in place of a proton adds 21.98 daltons to the neutral mass; potassium adds 38.09.
Why is net content different from the label figure? Net content is the weighed mass of the lyophilised solid, which carries counter-ion and residual water alongside peptide. The label figure is a nominal peptide target. They are different quantities.
How should a certificate be obtained? From the issuing laboratory’s own domain, using the accession or search code printed on it, rather than as a file forwarded by a seller — and after confirming the domain is the laboratory’s own and not a lookalike.
How is it stored? At −20°C, desiccated and protected from light.
This page anchors Clarion’s certificate-literacy series. The companion deep dives: “Sodium, potassium, and the ions that do not reconstruct” (the adducts), “Why every printed m/z sits a fraction low” (the residuals), and “Retrieve, then read” (pulling the certificate from the laboratory itself).
Retatrutide, CAS 2381089-83-2, C221H342N46O68, average molecular mass 4,731.33. Lyophilised powder. Current lot certificate: 99.72% by HPLC-UV, identity by LC-MS, signed by a principal chemist at Freedom Diagnostics Testing and hosted on that laboratory’s own domain.
For research use only. Not for human or animal consumption.