Average vs monoisotopic mass: why a peptide has two weights, and which one a COA uses
For qualified researchers. Clarion Peptides products are sold for laboratory research use only. They are not for people or animals. Updated November 10, 2026.
The short answer. A peptide has two weights. The average mass is the one on the label. The monoisotopic mass is the one a mass spectrometer sees first. They differ because some atoms come in heavier forms. To check a lab report, compare its mass with the monoisotopic number. For small peptides the gap is under one dalton. It grows as the peptide gets bigger.
Atoms come in more than one weight
Most carbon atoms are carbon-12. About 1.07% are carbon-13, which is one unit heavier.1 Hydrogen, nitrogen and oxygen have heavy forms too, but they are rarer. So in any vial of peptide, some molecules carry one or more heavy atoms and some carry none.
That gives two useful ways to state a molecule’s mass:
- Average mass uses the natural mix of heavy and light atoms. It is the weight of a typical molecule in a large pile. This is the “molecular weight” on a label or spec sheet, in g/mol or daltons.
- Monoisotopic mass counts only the lightest form of each atom: carbon-12, hydrogen-1, nitrogen-14, oxygen-16. It is the mass of the lightest molecule in the pile.
Tables of atomic weights round a little differently, so two average masses for the same peptide can disagree in the second decimal place. The monoisotopic mass is fixed by the formula.
The gap grows with size
A bigger peptide has more carbon atoms, so more chances to carry a heavy one. The last column shows the share of molecules with no carbon-13 at all, counting carbon alone.
| Peptide | Average and monoisotopic mass (Da) | No carbon-13 |
| Selank | 751.9 and 751.43 (gap 0.5) | 70% |
| Ipamorelin | 711.9 and 711.39 (gap 0.5) | 66% |
| Kisspeptin-10 | 1,302.4 and 1,301.63 (gap 0.8) | 51% |
| Thymosin Alpha-1 | 3,108.3 and 3,106.50 (gap 1.8) | 25% |
For Selank, about 70% of molecules have no carbon-13, so the lightest form is also the most common one. For Thymosin Alpha-1, only about 25% do. Most of its molecules carry at least one heavy carbon. On a spectrum, that shows up as a cluster of peaks one unit apart, and the tallest peak is not the lightest one.
Charge changes the number on the report
A mass spectrometer measures charged molecules. It reports mass divided by charge, written m/z. A peptide usually picks up one or more protons, and each proton adds 1.00728 to the mass.2 So:
- [M+H]+ is the mass plus one proton.
- [M+2H]2+ is the mass plus two protons, divided by two.
- [M+3H]3+ is the mass plus three protons, divided by three.
The gap between the two masses shrinks the same way. A 0.8 Da gap becomes 0.4 at a charge of 2.
Checking a real report
Our Freedom Diagnostics report for Selank prints [M+H]+ at 752.4.4 From the monoisotopic mass, the expected value is 752.44. From the average mass it would be 752.91. The report matches the monoisotopic number. That is what you expect for a small peptide, where the lightest form is also the most common.
Our Kisspeptin-10 report prints [M+2H]2+ at 651.9. The monoisotopic value is 651.82. The average-based value would be 652.23. Again, the report sits closer to the monoisotopic number.
If you compare a report with the label weight instead, a correct result can look off by most of a dalton. For large peptides, the reverse can happen: a lower-resolution instrument may report the middle of the cluster, which sits nearer the average. Our page on why printed m/z values sit slightly low covers that case.
A quick way to check any report
- Find the peptide’s formula from a source you trust, such as PubChem.
- Get the monoisotopic mass. Our peptide mass reference lists it, plus the usual charge states, for 22 peptides.
- Match the report’s ion to the same charge state. Small differences of a few tenths are normal.
- A miss of about one dalton can also mean a different end on the molecule. See what the “-NH2” at the end of a sequence does to the mass.
Sources
- NIST. Atomic Weights and Isotopic Compositions, entries for carbon, hydrogen, nitrogen, oxygen and sulfur. physics.nist.gov. Carbon-13 abundance 0.0107.
- NIST. CODATA value: proton mass in u, 1.007 276 466 5789. physics.nist.gov.
- PubChem formulas: Selank, Ipamorelin, Kisspeptin-10, Thymosin Alpha-1 (thymalfasin).
- Freedom Diagnostics Testing reports Clar2607240045 (Selank) and Clar2607240041 (Kisspeptin-10).
All Clarion Peptides products are for laboratory research use only. Not for human or veterinary use. Nothing on this page is a claim about the effects of any compound.
