The short answer. Our current PT-141 lot is P41. Its lab report comes from Freedom Diagnostics Testing. We sent the sample to the lab ourselves. The report says the vial holds the right molecule. It measured 99.83% purity and 9.02 mg of PT-141 in a 10 mg vial. You can open the same report on the lab’s own website. Below, every line of the report is explained.

The report at a glance

Laboratory Freedom Diagnostics Testing, Franklin, Tennessee
Client Clarion Peptides. We sent this sample to the lab ourselves.
Search code Clar2607240044 (accession 2607240044)
Dates Received July 24, 2026. Reported July 28, 2026.
Lot on the report P41
Product on the report “PT-141 10mg”
Identity Confirmed by LC-MS (checked below)
Purity 99.83% by HPLC with UV detection. The chromatogram is on the report.
Net content 9.02 mg measured
Lab’s own copy coas.freedomdiagnosticstesting.com/Clar2607240044.pdf

Check the identity yourself

PT-141’s formula is C50H68N14O10. From the formula alone, its monoisotopic mass is 1,024.52 Da. A mass spectrometer usually sees the molecule carrying one or two extra protons, so these are the numbers to look for:

  • [M+H]+ near 1,025.53
  • [M+2H]2+ near 513.27

The report shows [M+2H]2+ at 513.4 and the [M+H]+ signal near 1,025 to 1,026. Those match. You can do this math without trusting anyone, because the expected numbers come from the formula. Our peptide mass reference lists the same numbers for 22 peptides.

What the numbers mean

Purity is the share of the HPLC signal in the main peak. It tells you how clean the peptide is. It does not tell you how much of the powder’s weight is peptide.

Net content is how many milligrams of peptide the lab measured in the vial. The vial is labeled 10 mg, and the lab measured 9.02 mg, about 10% under the label. We show the number exactly as the lab reported it.

What this report does not show

Like most research-peptide reports, it has no water content, no counter-ion (salt) content, no amino-acid analysis, no endotoxin or sterility test, and no retest date. If your work needs those numbers, ask before you buy. Our guide to reading a peptide COA explains each one.

How to check it with the lab

  1. Open the report on Freedom’s own server: coas.freedomdiagnosticstesting.com/Clar2607240044.pdf. Or search the code Clar2607240044 in Freedom’s public COA lookup.
  2. Compare it with the copy you were given. If the two differ, the lab’s copy wins.
  3. Match the lot. Our vial labels don’t carry a lot code, because the label material can’t be printed on. Instead, a certificate card ships with the vials, and its QR code opens the lab report for the lot you received. The PT-141 product page and the Public Lot Ledger also list lot P41.

More on PT-141

The PT-141 buying guide covers the five checks to run on any seller’s PT-141, including ours. How to check any report with its lab: clarionpeptides.com/verify/.

When this lot sells out, the product page and the ledger show the next lot first. All Clarion Peptides products are for laboratory research use only. Not for human or veterinary use. Nothing on this page is a claim about the effects of any compound.